Mini Ductless Split Air Conditioner 36000 BTU
24000 BTU Dual Zone Energy Star Mini Split AC
22.5 SEER Efficiency w/ Heat Pump Technology With a 24000 BTU total Cool / Heat Capacity, the Hyper Heat
Thermocore T7HH23D-H224-12+12 Ceiling Cassette Energy Star mini split air conditioner can cool or heat 2 separate zones of 12000 & 12000 BTU for a total coverage area of 1200 ft² (600 ft² + 600 ft²). Most Energy Efficient Dual-Zone series in the market! A 22.5 SEER coupled with Inverter technology provides the benefits of low operation temps (-22F) as well as maximum energy efficiency. R454B precharged for 50ft of total lineset.
Technical Data:
System Includes:
- 24,000 BTU INVERTER Cooling Capacity: 12k x2
- 24,000 BTU INVERTER Heat Pump Capacity: 12k x2
- 22.5 SEER - 11 HSPF - 13 EER / ENERGY STAR Certified*
- 1 Year Parts - 5 Year Compressor Warranty
- Indoor Units - Cassette Air Handler.
- 24k BTU Outdoor Unit.
- Wall Mount Thermostat - Remote Control
- Product and Installation Manual.
** Extend 1 year parts - 5 year warranty package to 3 year part / 7 year warranty for $130 / year. Top Line Features:
- 23 SEER - 11 HSPF - ENERGY STAR
- Most Energy Efficient Dual-Zone Series on Market
- Dry-Mode removes moisture w/o affecting room temp
- Cross Flow Technology reduces noise output
- Built in Condensate pump included
- Freon Leak Detection > Notification system
- Low Ambient Temperature Operation (-22° F)
- Two-direction Air vane Evenly Distributes Air
- Restart IC: Settings restored Following Power Outage
- Follow-Me Function tracks Remote Location
Model Number T3-OS212-EC
Capacity 12000 BTU
Air Flow (Hi/M/Lo) 620/520/410 (m3/h)
Power Supply 230 V / 60 Hz / 1Ph
Noise Output (Hi/M/Lo) 50/47/43 dBA
Liquid / Gas 1/4" x 1/2"
Weight 39 lbs
Body Dimension (W x D x H) 22.44" × 22.44" × 10.24" inches
Panel Dimension (W x D x H) 25.47" x 25.47" x 2" inches
Model Number T7HH25D-H224-C
Rated Capacity 20000 BTU
Maximum Capacity 27600 BTU
Air Flow 2131 CFM
Power Supply 230 V / 60 Hz / 1Ph
Max Fuse Size 25A
SEER 22.5
EER 13
HSPF4 10.2
Outdoor noise level 62 dBA
Operating Temp Range -22~122/ -22~75 (cool / heat)
Refrigerant R454B / 78.31 oz
Pre-Charge Length 75ft (25ft x 3)
Liquid / Gas 1/4" x 3/8" (3)
Max Lineset Length (1 zone) 98 ft
Max Lineset Length (all zones) 197 ft
Compressor Brand TOSHIBA - GMCC
Weight 137.25 lbs
Dimensions (W x D x H) 37.24 x 16.14 x 31.89 inches
Install Kit Contents:
- 15 Feet Flared Copper Tubing x 2
- 15 Feet Pipe Insulation x 2
- 15 Feet Electrical Wire x 2
- Drain Pipe (connected to Indoor)
- Pre-Filter 'Particle' Filtration Media x 2
- Ceiling Brackets for Indoor Unit x 2
- Brass Adaptors for Alternate lineset sizes
- Installation and User Manuals
** Extend included 15 foot lineset to 25-30-40-50-65 feet. Just $4.50 / foot** WHAT IS DC INVERTER? DC Inverter Air Conditioners are the ultimate cooling and heating technology of the HVAC field. They are called "DC inverter" because the alternative current (AC) is converted to Direct Current (DC) then, direct current inverted back to Alternative current with desired frequency. As known, the current supplied through the wall outlet has fixed frequency which is 60 Hertz. Different frequencies supplied to the compressor will result different running speeds of the compressor. YMGI Inverter control systems use Pulse Amplitude Modulation (PAM) that is the most advanced and energy efficient method of inverting the current. DC Inverter air conditioners bear special compressors that their speed could be changed by increasing or decreasing the frequency of the supplied power. Therefore, unlike conventional split Air Contioners/Heat Pumps which cycle between on and off repeatedly, the DC Inverter control system will monitor the room temperature and adjust the compressor speed automatically.
Conventional compressors turn on and off to maintain the room temperature at desired level. This will result compressor to draw tremendous energy each time it starts up. This will also reduce the life-span of the compressor and other components that are turning on and off. Once a conventional system is running, it runs at its maximum speed, consuming the maximum amount of energy in order to produce the maximum of cooling or heating to maintain the desired temperature. The system will then cycle between on and off in an effort to maintain this temperature. When a DC Inverter compressor initially starts up, it runs with a higher speed to bring the room temperature to desired level rapidly. Once the set temperature is reached, it slows down and adjust its capacity to counter the heat loss or heat gain of the building. By this way it will maintain a constant temperature.
BASIC OVERVIEW: The indoor unit is hung like a picture frame approximately 6 - 8 feet above the floor usually on an exterior wall. A 2-3 inch hole must be made behind the indoor unit in the exterior wall to run the refrigerant copper tubing, electrical wires to the outside unit. Electrical Cables are NOT INCLUDED. The condensing unit comes pre-charged with R410A Freon however, procedures such as conducting leak tests etc. are still important steps in ensuring proper functioning of a split AC. *Although installation may seem easy to some, certain tools and experience is necessary to complete setup of a mini splitIt is highly advised a certified HVAC technician complete installation to be eligible for warranty. See warranty details below >
*5 Year Compressor - 1 Year on all other Parts* Registration card will be sent with unit, this card should be completed by an HVAC technician (installer). Installation of a mini split must be completed by a licensed HVAC (Heating, ventilating, & air conditioning) company to ensure any issues encountered in the future are not due to improper installation / workmanship. Even though mini split setup is below the expertise requirements of central AC systems, these are not "plug-n-play" units that can be properly installed without certain tools any prior HVAC - electrical knowledge. The installation includes electrical, gas, and refrigerant connections and generally regulated by a multiple sets of laws, codes and guidelines, at the federal, state and local levels. The failure to properly install HVAC equipment can raise personal safety and performance concerns. Warranty service - troubleshooting is provided through the contractor / installer and will be upheld as long as policies are observed. Once a non-defective unit is installed by a HVAC company, chances of anything going wrong are very slim and almost all contractors will guarantee there workmanship and provide future service free of charge (installation warranty). If it was determined that the unit is not functioning due to a defect and needs to be replaced, the part will be sent free of charge up to 1 year from date of purchase or 5 years for the compressor. If you receive a damaged or defective product, a replacement unit will be sent out Free of cost. Damaged / Defective product will be picked up and brand new exchange will be shipped out.
SHIPS TO TO BOTH UNITED STATES AND CANADIAN LOCATIONS! Our Thermocore systems ship via RL Carriers or similar LTL freight service out of Warren, Michigan and are palletized onto a single skid. Transit time is usually between 4 to 6 business days from payment receipt depending on where you are geographically located. Please provide a contact phone# upon checkout (to be used for delivery purposes only). SOMEBODY MUST BE ON SITE TO ACCEPT / SIGN FOR Order. Failure to provide valid contact# will delay order. System comes with Free shipping - this includes delivery to any location within the Continental United States. We will ship to Canadian locations but we need to quote separately - please contact our offices. Additional freight for Canadian registries is usually around $150. (import and duties may apply).